just:in linux is not activated by default and therefore a ToolOnAir watermark will be added to all Recordings

Activation is not required to test just:in linux engine or the Just Control application.

Activate a Device

Open the Just Control Configuration panel, select a Device and switch to the “Activation” tab.

To make any changes you have unlock the Just Control Configuration panel.

Copy and Paste the Activation Key, you have received, into the “Activation Code” field and either press the "Enter" key or the "Activate" button. When the Activation was successful the Activation status in the Activation Status and Option List changes from Yellow to Green.

Please make sure that the just:in linux engine gets restarted after adding the Activation Key.

Switch Activation between Channels

If you are working with frequently changing setups, like for instance using four licensed SDI channels (e.g. JIL-4), and you need to change that configuration to use three of these SDI channels with one (1) additional NDI®5 or SRT channel, then please make sure that you only enable the number of licensed channels in use (in our case 4 channels) and not all of them, as you might exceed the number of totally licensed channels on that particular just:in linux appliance.

Please make sure that you restart the just:in linux engine, after you are changing the enabled channels.