Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note

You must unlock the Just Control Configuration window and stop the channel(s) first to be able to make perform any changes.

Assigning an Engine to a Channel using 2N Redundancy

It is possible to assign an a Just Out engine as the redundant engine using the 2N 2N” setup. In such environmentsthis configuration, each Channel has a Primary engine and a dedicated Redundant engine assigned to it, where both Just Out engines are playing out the same content at the same time.

  1. Go to the Advanced Advanced” tab.

  2. Activate the Redundancy Redundancy” checkbox.

  3. Select Full (2N).

  4. Go to the Layers & EnginesEngines” tab.

  5. On the right side there's a column called , look for the column named “Redundant just:out EngineEngine”.

  6. Click on Select Engine…Engine…” under the Redundant just:out EngineEngine” tab and choose the Engine Just Out engine you would like to assign to this layer Layer.

  7. Repeat this for each Layer which that has no Just Out engine assigned.

Info

Because you selected Full (2N)as redundancy type, you can assign the same Just Out only once engine to a Channel only once.

Assigning an Engine to a Channel using N+1 Redundancy

It is possible to assign the same Engine Just Out engine to several Channels as the Redundant Engine using the N+1 1” setup. In such environmentsconfigurations, several various Channels are sharing share the same Redundant Engine (which helps to save costs Just Out engine (cost-effective). This implies that only one Primary Engine Just Out engine can fail at a time.

  1. Go to the Advancedthe “Advanced” tab.

  2. Activate the Redundancythe “Redundancy” checkbox.

  3. Select Select “Flexible (N+1).

  4. Go to the the “Layers & EnginesEngines” tab.

  5. On the right side there's a column called , look for the column named “Redundant just:out EngineEngine”.

  6. Click on Select Engine…Engine…” under the Redundant just:out EngineEngine” tab and choose the Engine Just Out engine you would like to assign to this layer Layer.

  7. Repeat this for each layer which Layer that has no Engine Just Out engine assigned.

Info

Because you selected N+1as redundancy type, you can assign the same Just Out engine to several Channels (using N+1 1” redundancy) as the redundant Engine Redundant Just Out engine.